Technical Data

 
Basic Machine System
 

Technical Data

Active scan and measuring area

X-axis:

700mm (27.5 Inch)

Y-axis:

650mm (25.6 Inch)

Total system accuracy with the Metrology system QC5000:

U1 = 2,5 + L/300

MSA test 1 Cgk > 1.33 on T = +/- 0.030mm

(min. magnification 150x)

System resolution

X and Y-axis:

0.0002mm (0.2µm)

Z-axis:

0.0002mm (0.2µm)

Axes speed

XY axes speed:

500 mm/s

XY axes acceleration:

1000 mm/s²

Machine weight:

approx. 3.000 kg

Pressured air:

min. 0.68 MPa (6.8 Bar), 100 NL/min.

Power:

400 Volt, 3 Phase, 50/60 Hz, 25 A

 
 
QC5000 Metrology System
 

Technical Data

Type of camera:

Matrix CCD colour camera

Objective:

12x magnification objective (25x up to 220x)

Light options:

  • white LED sector bottom light
  • glass fibre ring top light
  • white LED coaxial light
  • red or white 4 sector LED ring light

QC-computer:

Intel DualCore 3.6 GHz, 2056 MB RAM, 160 GB HD, DVD, FD, Dual Network

Accuracy:

+/- 3 µm

Standard input format:

DXF file (default list format e. g. AutoCAD2000)

 
 
Highspeed Scanner System
 

Technical Data

Scan system

Scanning time on a 500 x 500mm board

< 60 seconds with 100.000 holes

Hole evaluation type:

  • centre of gravity analysis
  • best fit analysis

Contour evaluation type:

(contour evaluation optional extra)

  • best fit analysis

Scanning accuracy:

+/- 0.005mm

Diameter of possible holes:

0.080mm up to 6.5mm

Scanning speed:

180 mm/s

Track width:

approx. 80mm

Standard Input format:

DXF format (list format like AutoCAD2000)

Input format for the Imbach NC-DXF converter I and II:

Excellon 1 und 2, Posalux, S&M, DPF, Gerber

Special functions:

  • Automatic slot hole measuring
  • Contour measuring of circles, lines and arcs via scan process (optional)
  • Construction of distances, points and angles in the dxf-file (contour measuring)
  • Free programmable tolerance databases for holes and contour data

Scanning computer:

Pentium 4 3.6 GHz, 4096 MB RAM, 80 GB HD, DVD, FD, Dual Network

 
 

None-Contact, single point Laser Sensor System

 

Technical Data

Possible lens types:

30

40

50

Accuracy of the depth measuring process:

<3µm

<4µm

<6µm

Operation range during measuring process:

3mm

4mm

8mm

Working temperature range:

18 bis 35°C

Possible measurements:

    • point measurement
    • line measurement (many points)
    • plain measurement (many points)
    • topography measurements (many single points)
 
 

Optical KORAD 3D sensor System

 

Technical Data

Maximum size of the product:

480 x 680 mm

Maximum Thickness:

80mm

Scansize:

4x4mm up to 40x40mm (follows a  lateral resolution of 4 – 20µm)

Depth accuracy:

  • Optical rough surface: typical 1µm
  • Optical smooth surface: > 30nm

Camera types:

  • 1MPixel 500Hz 60µm/sec.
  • 4MPixel 120Hz 15µm/sec.